{"product_id":"sonatest-sitescan-500s","title":"Sonatest Sitescan 500S","description":"\u003ch3 class=\"fusion-woocommerce-tab-title\"\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Sitescan 500S offers the\u003cspan\u003e \u003c\/span\u003eNDT\u003cspan\u003e \u003c\/span\u003eend user an entry level broad band flaw detector with a full VGA display, sync and proportional outputs and a 50nS (Spike) 200V Pulser.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCustomisable \u0026amp; Intuitive Menus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eSplit DAC\/AVG\/DGS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eAngle Measurement Mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eConfigurable on-board software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eField Upgradeable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eEncoded B-Scan\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eA-Scan Fade\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e4GByte on-board memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eUSB Interface for PC import\/export\u003c\/li\u003e\n\u003cli\u003eVideo Output for training\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eSizing Techniques \u0026amp; Software Options include:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eDAC (Standard)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDefined by up to 20 reference points or converted from TCG curve and digitally drawn on the screen. DAC curves meet the requirements of EN1714, ASME, JIS and many other standards. Custom DAC curves can be selected. DAC dynamic range can be extended by automatically adjusting the reference curve to match the reference gain. Scanning Gain and T-Loss available as separate controls. Amplitude readout is selectable between %FSH, % DAC or relative dB.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSplit DAC \u0026amp; DGS\/AVG (Option)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAdds up to 3 zones of added gain (+12db, +24dB) to the DAC or DGS\/AVG curve to enable single-pass scanning of large sections and attenuative materials. Conforms to EN583-2:2001.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTCG (Option)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTime corrected or “Swept” gain, defined by up to 10 reference points or converted from a DAC curve. All points converted to 80% screen height.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBackwall Echo Attenuation (BEA) Option (requires TCG)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e0-40dB attenuation applied to the latter part of the time base, to improve the detectability of defects near the back wall and the loss of BWE due to porosity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAWS (Option)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBuilt-in calculation and display of factors and parameters required by AWS D1.1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAVG\/DGS (Option)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnables the calculation of pseudo “DAC” curve and equivalent reflector size of UT indications, based on user input of transducer parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPI (Option)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOn-board flaw sizing method in accordance with API 5UE.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Trigger (Option)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnlocks the interface trigger gate controls, which hold off the A-Scan acquisition and display until an interface echo is detected within a specific range and amplitude. Used for the elimination of water-path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosion Software (Option)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnables complex inspection plans to be uploaded from a PC using the on board Utility software. Features include 2 dimensional thickness logging, storing A-Logs and B-Logs with thickness values, taking multiple readings per location and note creation for each grid location. A B-Scan option available to display bar-graph views of thickness readings taken by Gate 1 against distance or time.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Russell Fraser Sales","offers":[{"title":"Default Title","offer_id":47724898484401,"sku":"SS500LKIT","price":15499.99,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/5211\/8449\/files\/SonatestSitescan500S1.webp?v=1784525343","url":"https:\/\/testingcore.com\/products\/sonatest-sitescan-500s","provider":"TestingCore","version":"1.0","type":"link"}